THERMAL CONDUCTIVITY & R VALUE

DOKUZ EYLUL UNIVERSTY, IZMIR / TURKEY ENGINEERING FACULTY
DEPARTMENT OF MECHANICAL ENGINEERING

REPORT
Subject: Evaluation of Thermal Conductivity Coefficient
Company: DBS Insaat Taah Kimya San ve Tic Ltd Sti
 

Material received by our department (Wall Mix G and Wall Mix W) were tested with the QTM machine, utilizing the hot wire method. Resulting average thermal conductivity values are given below:

 
Sample Name
Testing Environment
Temperature (C)
Thermal Conductivity
Coefficient (W/mK)
Wall Mix G
25
0,661
Wall Mix W
25
0,787

- Thermal resistance (R value) = L/k, measured in Km2W-1
 

According the average thermal conductivity values of Wall Mix G and Wall Mix W, thermal resistance values may calculate with different thicknesses like given examples below:

R Values Km2W-1
Wall Mix G
Wall Mix W
0,5 cm thickness of application
0,008 m2K/W
0,006 m2K/W
1,0 cm thickness of application
0,015 m2K/W
0,013 m2K/W
2,0 cm thickness of application
0,030 m2K/W
0,025 m2K/W
2,5 cm thickness of application
0,038 m2K/W
0,032 m2K/W